Dry Sealed Batteries (MF) is used as a way to power:
1 The office equipment, battery backup for UPS, Inverter, Solar, Telecom, the Svetlana ...
2 emergency lighting.
Third computer, the power supply when the power network outage.
4 Light guide.
5 The communication device.
6 Operation of the device.
7 The measuring equipment.
8 alarm system.
9 power transformer station
10 Start the car and motorcycles ....
Product Code |
N200 |
|
Voltage |
12 |
Volt |
Capacity |
210 |
Ah |
Length |
518 |
mm |
Width |
276 |
mm |
High |
217 |
mm |
Total height |
237 |
mm |
Electrode |
Lead Alloys |
Sealed batteries dry (KK) is not maintained (Maintenance Free - MF) bringing brands TS, PHOENIX, EVERSUN, ELNIKA by Company Tia Sang Battery manufacturing technology in the Korean device U.S., Italy and South Korea lead battery types - acid contained in the dry many advantages compared to traditional batteries, which are:
1 - Structure of leakage:
Use the leaves to absorb. All electrical service panels are adsorbed in the anode, cathode and leaves the way. By designing this special seal will not leak fluid and can be safely used for any device and in any position.
2 - No need to maintain the operation:
No need to check the proportion of electricity service or additional water during battery use. Battery completely closed and just charge for maintenance.
3 - The low self-discharge:
Self-discharge is reduced to a minimum by using ultra-alloy lead frames - calcium (Pb - Ca).
4 - No corrosive gas emissions:
Battery Sealed design incorporated a controller capable of generating the gas and allow the batteries together in more than 99%, the amount of gas generated during use in standard conditions.
5 - The ability to recover quickly after deep discharge:
The leaves absorb the fiberglass components particularly improved balance sheet and positive electrical system service, always improving battery capacity recovery after deep discharge.
6 - Safety in use:
Gas in the battery are combined together without getting out. Safety valves and filters ensure explosion-proof structure when the load.
7 - You can use the connection capacity by more normal and parallel to each other:
Batteries can be used to power by connecting to the normal parallel to each other and play up to three circuits that serial.
User dunes:
1. Put new batteries in use:
* Check the status of battery power no:
Sealed dry battery factory pre-loaded power should be used immediately. During the installation process should use caution, avoid extreme short-short-circuit both ends may explode or burn per head. Before you put to use, check the voltage:
* In the process of not using additional water and electric service ratio test (not opening the side).
* When the battery discharges, if the voltage drops 1.80 Volt / compartment (U = 10.80, respectively Volt with battery 12V) to stop the discharge and recharge the battery just is not for power hungry long (see section 2 ).
2. Battery charging:
When the battery has run out or release unused for long periods have recharged the battery by:
Battery of 2V |
Women often loaded |
Load voltage |
¸ 2.25 V 2.35 V |
Maximum load line (A) |
£ 0.25 stated value per volume |
||
Load cycles |
Load voltage |
¸ 2.40 V 2.50 V |
|
Maximum load line (A) |
£ 0.25 stated value per volume |
||
Battery type 12V |
Women often loaded |
Load voltage |
¸ 13.5 V 13.8 V |
Maximum load line (A) |
£ 0.25 stated value per volume |
||
Load cycles |
Load voltage |
¸ 14.40 V 15.00 V |
|
Maximum load line (A) |
£ 0.25 stated value per volume |
3. Preservation and storage batteries:
* New Sealed batteries dry if not used must be kept dry, cool place. Avoid short circuit for bringing electricity available.
During storage, storage should periodically charging additional schedule follows:
* Dry Sealed Batteries are the temporary use if no longer use must be cleaned, preserved in dry, cool. Periodically additional charge as items 2 and 3.
4. Battery Warranty:
- Lead-acid batteries, sealed dry by Battery Corporation flares produced 06 month warranty from date of purchase. You need to warranty the battery purchase invoice and warranty in accordance with warranty battery needs.
- During the warranty period if the battery damage due to fault of the manufacturer shall repair or exchange company, the customer does not pay.
- The Company does not warrant the battery due to customer misuse, as instructed, catch fire, breakage, bark chips or changes the individual traces of the manufacturer.