Moving from DC to 12VDC low voltage alternating current high voltage 220VAC 50Hz 12VDC battery to source comments civil, motorcycles and cars.
- Special: + high voltage stability. + Lower operating costs + No noise, no fuel costs, not bulky, does not cause environmental pollution as generators running.
- Scope of use: Can be used for lighting, television, CD player, video, staging computer, telephone, fax machine, industrial sewing machines, drilling machines, electric fans, air conditioners, air welding, water pumps, internet shop or company, office buildings ...
Batteries:
- Customers can use the battery or dry batteries are:
- Voltage Average: 12 vol
- Average size: 50Ampe, 100Ampe, 150Ampe ...
- Depending on user needs (power, duration of use) customers to choose appropriate type of comments, we will advise the customer details.
HOW TO USE:
- Just a battery Vol 12, 100Amp or more and is connected to power adapter Power Inverter that you will have the power to use electrical appliances in the home.
- Time can be used from 1 to 24 hours depending on battery capacity and use.
Appliance |
Power Consumption |
Type of battery |
Using time (h) |
Lighting, fan, television |
150w |
12V - 100Ah |
6.4h |
12V - 150 AH |
9.6h |
||
12V - 200Ah |
12.8h |
||
12V - 300Ah |
19.2h |
||
12V - 400Ah |
25.6h |
COST COMPARISON
Between two options: Use the device to change power schemes using generators.
The plan |
Power supply |
Cost |
Power adapter + battery 150 AH |
1.5 Kw |
Charging costs: 1.5kW x 650 USD = 975 USD |
Running the generator power: 1.5kW / h |
1.5 Kw |
1 hour run out 0.5 liters of gasoline = 8,450 USD |
Use generators nearly 10 times more expensive than using electrical equipment change |
Products |
LW1500 |
LW3000 |
LW4500 |
LW6000 |
LW7500 |
LW9000 |
|||||||||
The input waveform |
Standard sine wave (utility power) |
||||||||||||||
Nominal voltage |
220VAC |
||||||||||||||
Low voltage trip |
184v/154v + 4% |
||||||||||||||
Connect the low voltage |
194v/164v + 4% |
||||||||||||||
High voltage trip |
253v + 4% |
||||||||||||||
Connect the high voltage |
243v + 4% |
||||||||||||||
AC input voltage high |
270VAC |
||||||||||||||
Nominal input frequency |
50Hz or 60Hz (auto detect) |
||||||||||||||
Low frequency trip |
47Hz to 50Hz, 57Hz to 60Hz |
||||||||||||||
High-frequency trip |
55Hz to 50Hz, 65Hz to 60Hz |
||||||||||||||
The output waveform |
(Skip mode) as input |
||||||||||||||
Overload protection |
Circuit breaker |
||||||||||||||
Short Circuit Protection |
Circuit breaker |
||||||||||||||
Convert evaluation |
30amp or 40amp |
||||||||||||||
Effective transit time flow |
95% + |
||||||||||||||
Time line transfer |
10ms typical |
||||||||||||||
Report no battery connected |
yes |
||||||||||||||
Max ignores current |
30amp or 40amp |
||||||||||||||
Skip overload current |
35amp or 45amp: Alarm |
||||||||||||||
The output waveform |
Standard sine wave |
||||||||||||||
Watt continuous power output |
1000 |
2000 |
3000 |
4000 |
5000 |
6000 |
|||||||||
VA continuous output power |
1000 |
2000 |
3000 |
4000 |
5000 |
6000 |
|||||||||
Power Factor |
0.9-1.0 |
||||||||||||||
Nominal output voltage rms |
220V + 5% |
||||||||||||||
Output voltage adjustment |
10% rms |
||||||||||||||
Frequency |
50Hz or 60Hz + + 0.3Hz 0.3Hz |
||||||||||||||
Nominal effective |
> 88% |
||||||||||||||
Increased ratings |
3000 |
6000 |
9000 |
12000 |
15000 |
18000 |
|||||||||
Short Circuit Protection |
Error after 10 seconds |
||||||||||||||
Nominal input voltage |
12V |
24V |
48V |
||||||||||||
A minimum starting voltage |
10V |
20V |
40V |
||||||||||||
Report on principal sources |
10.5V |
21V |
42V |
||||||||||||
Pin weak |
10V |
20V |
40V |
||||||||||||
High voltage alram |
16V |
32V |
64V |
||||||||||||
Power saver |
Below 25watts activation |
||||||||||||||
Power saver |
Similar to the on / off on remote control |
||||||||||||||
Input voltage range |
194-243VAC / 164-243VAC (W) |
||||||||||||||
Output voltage range |
Depending on the type of battery |
||||||||||||||
Lines of |
35A/70A |
||||||||||||||
Battery initial voltage for start |
0-15.7v for 12v (24v * 2; * 4 to 48V) |
||||||||||||||
Overcharge protection shutdown |
15.7v for 12v (24v * 2 for; * 4 for 48V) |
||||||||||||||
Control xa/RS232/USB |
There are, Options |
||||||||||||||
Dimensions in mm |
1000/2000/3000 Model: 442 * 218 * 179 |
||||||||||||||
Dimensions in mm |
4000/5000/6000 Model: 598 * 218 * 179 |
||||||||||||||
Net weight |
LW1000 |
LW2000 |
LW3000 |
LW 4000 |
LW5000 |
LW6000 |
|||||||||
Net weight |
18kgs |
20kgs |
22kgs |
35gs |
38kgs |
40kgs |
|||||||||
Retail price (USD) |
7,999,000 |
12,950,000 |
15,500,000 |
22,450,000 |
26,560,000 |
29,500,000 |